Hi guys,

 

recently I have joined a BPM implementation Project which consists of several process definitions.

These processes should talk to each other. Therefore I modeled the async communication between two of them using intemediated message events.

process A should start process B by sending a message.

The wsdl I defined for process B consists of two operations (startProcess and cancelProcess)

During maintain the properties of the automated activity in process A, I created a new service group and attached the service reference to it. Beside this service group there are already other Service groups available, one Service group which include objects of another inter-process communication another include rules interfaces and one including interfaces of the JEE DC.

All the processes running on the same AS Java.

After deployment I had a looked at the service group in the "application communication" section in NWA and there I am facing an error while trying to assigning the service group to the AS Java as provider system.

 

Following error message ist visible in the log

Configuration for service group [PROJ_A_BPM_SG] failed. Error details:

[No endpoints found. Check if the service is configured and if its endpoints are available in the WSIL. Service: [{http://test.com/FollowUpProc/}FollowUpProc]  Assigned Provider: [CE3 on server1.test.local]

Service Group: [PROJ_A_BPM_SG]

Service Group application: [test.com/proj_A~desk~bo~bpm]

Service Reference application: [test.com/proj_A~desk~bo~bpm]

- com.sap.engine.services.webservices.espbase.query.exceptions.TechnicalException: There is more than one implementation of the same web service interface on that provider system. This is not supported. See SAP note 1606439 for further information and how to resolve that issue. Details:[proj_A~desk~bo~bpm_FollowUpProc_testcom2Fproj_A2Fdesk2Fbo2Fbpm2FFollowUpStart_FollowUpProc,proj_A~desk~bo~bpm_FollowUpProc_testcom2Fproj_A2Fdesk2Fbo2Fbpm2FFollowUpCancel_FollowUpProc] for portTypeName [{http://test.com/FollowUpProc/}FollowUpProc], PROJ_A_BPM_SG]

For more information refer to the trace with ID [C000C0A8013B00090000022F00001314]. Details: [CE3.SystemHome.server1.test.local.Java] provider system, [test.com/proj_A~desk~bo~bpm] service group application

 

I have no clue why there should be more than one implementation. When I manually configure the service reference the communication works fine.

 

Does anybody have an idea what could be the reason for this error message while using automated assignment.

Maybe I missed any step.

 

Any help appreciated.

 

Best regards,

Jochen